สถาบันวิจัยแสงซินโครตรอน (องค์การมหาชน)

font size:

Social:

Technology / Beamline System / Beamline 8W

Facility and Equipment Availability

Facility and Equipment Availability

Facility and Equipment Availability

Automation Sample Changer

Fig. 1 Mounting the sample on the sample holder and inserting it into the sample chamber Fig. 1 Mounting the sample on the sample holder and inserting it into the sample chamber Fig. 1 Mounting the sample on the sample holder and inserting it into the sample chamber Fig. 1 Mounting the sample on the sample holder and inserting it into the sample chamber
Fig. 1 Mount the sample on the sample holder and insert it into the sample chamber.
Important: After installing the sample, take a photograph of the sample together with a scale ruler, ensuring that the beam center aligns with the ‘0’ mark on the ruler.

In-situ Heating Cell

Fig. 2 In-situ heating cell: room temperature – 800 °C Fig. 2 In-situ heating cell: room temperature – 800 °C
Fig. 2 In-situ heating cell: room temperature – 800 °C

The heating cell is capable of operating from ambient temperature to 800 °C, with a maximum heating ramp rate of 20 °C/min.

Fig. 3 Diagram of continuous heating and stepwise heating of the sample Fig. 3 Diagram of continuous heating and stepwise heating of the sample
Fig. 3 Diagram of continuous heating and stepwise heating of the sample.

Support Lab

Siam Photon Laboratory (SPL) provides advanced instruments and facilities to support users:

  • Dry Lab tools: pestle and mortar, tweezers, spatulas, etc.
  • Precision Balance (2-Decimal Place)
  • Analytical Balance (4-Decimal Place)
  • Fume Hood
  • Hot Air Oven
  • Mini Mill
  • Hydraulic Press 15-Ton
  • Magnetic stirrers
If you require any additional equipment or have specific needs, please contact the staff in advance to ensure availability.

Available Standards in Beamline 8

Click on an element to view its absorption edge energy (eV) and fluorescence line energy (keV).

1 H
2 He
3 Li
4 Be
5 B
6 C
7 N
8 O
9 F
10 Ne
11 Na
12 Mg
13 Al
14 Si
15 P
16 S
17 Cl
18 Ar
19 K
20 Ca
21 Sc
22 Ti
23 V
24 Cr
25 Mn
26 Fe
27 Co
28 Ni
29 Cu
30 Zn
31 Ga
32 Ge
33 As
34 Se
35 Br
36 Kr
37 Rb
38 Sr
39 Y
40 Zr
41 Nb
42 Mo
43 Tc
44 Ru
45 Rh
46 Pd
47 Ag
48 Cd
49 In
50 Sn
51 Sb
52 Te
53 I
54 Xe
55 Cs
56 Ba
57 La
58 Ce
59 Pr
60 Nd
61 Pm
62 Sm
63 Eu
64 Gd
65 Tb
66 Dy
67 Ho
68 Er
69 Tm
70 Yb
71 Lu
72 Hf
73 Ta
74 W
75 Re
76 Os
77 Ir
78 Pt
79 Au
80 Hg
81 Tl
82 Pb
83 Bi
84 Po
85 At
86 Rn
87 Fr
88 Ra
89 Ac
90 Th
91 Pa
92 U
93 Np
94 Pu
95 Am
96 Cm
97 Bk
98 Cf
99 Es
100 Fm
101 Md
102 No
103 Lr
104 Rf
105 Db
106 Sg
107 Bh
108 Hs
109 Mt
110 Ds
111 Rg
112 Cn
113 Nh
114 Fl
115 Mc
116 Lv
117 Ts
118 Og
57–71
89–103
K-edgeL-edgeM-edgeNot accessible at BL8⊕ Reference standard available

Data Backup

Data Storage

  • Experimental data are stored according to each beam cycle and organized by the user’s project (Proposal ID).
  • Data are stored on the online file server and on HDD backups for a period of approximately 5 years.

Data Delivery

  • Users may transfer their data directly via email using the computer available at the experimental station.
  • Alternatively, you may request the beamline staff or your project coordinator to send the data to you via email afterward.

Experimental Feedback

The Institute kindly requests all synchrotron users to submit the following reports after completing their beamtime:

  • End of Experiment Feedback: Please complete the post-experiment satisfaction evaluation through the BeamApp system after your experiment.
  • Experimental Report: Please submit a report summarizing the experimental results within 14 days after the completion of the experiment via BeamApp.