The primary advantage of the TRXAS end-station is its ability to record complete X-ray absorption spectra simultaneously and rapidly. This makes it an ideal tool for in-situ measurements to monitor structural and electronic changes in samples under various environmental conditions, such as high temperature, pressure, or specific gas atmospheres.

In-situ Environmental System

Currently, the institute provides a specialized Heating Cell designed to support a wide range of in-situ research applications, enabling simultaneous temperature control and atmospheric regulation.

Technical Specifications

FeatureDetails
MaterialStainless Steel Body
Body Dimensions45 x 45 x 70 mm
Sample Holder16 mm diameter (pre-drilled hole)
WindowsDual Kapton windows with water cooling system
Heating Source6X Cartridge Heaters (8 mm OD, 250 W each)

Temperature Control

Maximum Operating Temperature973 K (700 °C)
Ramp Rate5-20 °C/min
ControllerEurotherm 2216e with K-type thermocouple
Stability± 0.1 K

Gas Atmosphere & Flow Control

The cell is designed to accommodate various gas environments for catalytic and material study.

Available GasesN2, O2, He, Ar, CO2 and H2
Flow ControlAALBORG Mass Flow Controllers (MFCs)
Flow Rate Ranges0–100 sccm and 0–25 sccm

In-situ Battery System

The cell structure consisted of a cap, anode, separator, cathode, spring, and case. The coin cell (CR2032) with an OD of 20 mm was used. To assembling the cell, an anode (Li foil, 0.75 mm thickness), separator (Celgard2400, 25 μm thickness), cathode (LFP) and spring (stainless steel, 0.3 mm thickness) were provided. Since the case and cap were made from stainless steel, they did not allow x-ray transmission. Thus, the aperture with OD 8 mm and sealed with Kapton film were provided.

Coin Cell Analyzer 5V10mA Battery Testing System

Technical Specifications

AC InputAC 220V±10% 50Hz
Power25 W
ResolutionAD: 16bit; DA: 12bit
Input≥1MΩ
VoltageMeasuring RangeCharge:25mV~5V
Discharge: 25mV~5V
Discharge Min Voltage0V
Accuracy± 0.1% of FS
Stability± 0.1% of FS
CurrentRangeCharge: 0.05mA~10mA
Discharge: 0.05mA~10mA
Accuracy± 0.1% of FS
Stability± 0.1% of FS
PowerOutput Power Per Channel0.05W
Stability± 0.2% of FS
TimeRise Time1ms (0~Full Range)
Step Time≤ (365*24) hour/step
Time Format 00:00:00 (h:min:s)
Data AcquisitionIntervalsTime interval Δt:(1s~60000s)
Voltage interval ΔU: (10mV~5V)
Current interval ΔI: (0.02mA~10mA)
Frequency1Hz
ChargeMode of OperationCCC, CVC, CC & CVC
End ConditionsVoltage, Current, Test Time, Capacity
DischargeMode of OperationCCD, CPD
End ConditionsVoltage, Current, Test Time, Capacity
CycleCycles65535
Steps63
Nested FunctionMax three levels of loops

Detector System

To measure XAS spectrum, the position sensitive detector (PSD) is used.

S3904–1024F

NMOS Linear Image Sensor with Scintillator

(Hamamatsu Photonics K.K.)

NMOS linear image sensor consisting of 1024 pixels of an N-type diffusion layer formed on a P-type silicon substrate.

Detection Method

The use of an indirect detection method, employing an X-ray scintillator (150 μm thick CsI (Cesium Iodide) coated on a fiber optic plate) to convert X-rays into visible light, extended the sensor lifetime to over a year.

ParameterSpecification
TypeCurrent output type (with FOP)
Image Size25.6 x 2.5 mm
Number of Effective Pixels1024 x 1 pixels
Pixel Size25 x 2500 μm
Spectral Response Range360 to 1000 nm
Line Rate (max.)1950 lines/s
CoolingNon-cooled
WIndow MaterialFiber optic plate
PackageCeramic
Measurement ConditionTyp. Ta=25 ℃, unless otherwise noted
https://www.hamamatsu.com/us/en/product/optical-sensors/image-sensor/ccd-cmos-nmos-image-sensor/line-sensor/for-spectrophotometry/S3904-1024F.html

Absorption Edges Accessible at BL2.2

Click on each element with a  +  icon to view the available standard at BL2.2