Technology / Beamline System / Beamline 3.2 W

Facility and Equipment Availability

Facility and Equipment Availability

Beamline 3.2Ua/b · Photoemission Spectroscopy (PES) & PEEM

Facility and Equipment Availability

Equipment at each end station & support facilities

ARPES End Station

Equipment or ComponentDetails
Scienta R4000 hemispherical electron energy analyzer with +/- 15° angle multiplexing lens.Analyzer entrance slit vertical, along main rotation axis of manipulator for Fermi surface maps.
Six-degree-of-freedom sample cryogenic manipulator (Gold sheet is installed on the manipulator) from Fermi Instruments5-axis X, Y, Z, R1 (polar), and R3 (tilt) with control motor and R2 (azimuth) with manual screw. XYZ and angular axis accuracy is 0.01 mm and 0.1 deg.
  • Polar = -40, +20 deg
  • Tilt = -15, +40 deg
  • Azimuth = -120, +120 deg
Variable temperature 8 – 300 KTake 8 hours from room temperature to 8 K.
Sample check and orientation by LEEDMaximum at 1 keV electron energy
Evaporation deposition on sample surfaceTwo slots of alkali metal evaporated source (K, Na, Li). Requirements need to be discussed with beamline scientists.
Ar ion sputtering gunMaximum energy is 3 keV, and working pressure is ~10⁻⁶ mbar at preparation chamber
Gases flow into the preparation chamberAr, N₂, O₂, etc., gas flowing at the preparation chamber requirements need to be discussed with beamline scientists.
The MBE chamber is connected for annealing a sample or material deposition.The maximum temperature of the heater is 700°C, with a pressure base of 10⁻⁹ mbar. Material deposition needs to be discussed with beamline scientists.
Load-lock with 7 slots of sample holdersTakes 1.5 hours to pump down for preparing pressure to transfer a sample into the main chamber without breaking UHV
Electrical connection with manipulatorAvailable to apply a voltage bias to a sample or measure current on a sample.
Fermi BL1200s Multi-Gas Ultra-High Flux VUV source systemAn additional fixed VUV source component system with a He-discharged gas source and a monochromator generates photon energy of 21.22 eV

XPS End Station

Equipment or ComponentDetails
Hemispherical Electron Energy Analyzer: Thermo VG Scientific Alpha110Total minimum energy resolution at 200 meV and RT, and typical XPS Au4f7/2 FWHM is about 0.8 eV at the pass energy of 10 and photon energy of 400 eV
4-axis manipulatorX, Y, Z, and R1 (polar) 0-180 deg
Ar ion sputtering gunMaximum energy is 3 keV, and working pressure is ~10⁻⁶ mbar in the main chamber
Electron gunThe energy up to 5 keV
Load-lock with 2 slots of sample holder plateTakes at least 1.5 hours (depending on the sample type) to pump down for preparing pressure to transfer a sample into the main chamber without breaking UHV
Total Fluorescence Yield detectorHamamatsu photonics multi-channel plate
Electrical connection with manipulatorAvailable to apply a voltage bias to a sample or measure current on a sample.
Flux monitorGold mesh and photodiode
Large sample holder plate28 mm x 94 mm sample plate, able to load several samples in the main chamber (numbers of samples depend on the sample size).

PEEM End Station

Equipment or ComponentDetails
Hemispherical electron energy analyzer with Micro-channel plate, Sensicam QE CCD cameraModel: Elmitec PEEM III
Electron gun low-energy electron microscopy (LaB6 thermionic emission)LEED pattern, LEED-IV, EELS incidence electron energy from -10 to 500 V
3-axis manipulator with heaterThe sample can be heated by thermal filament up to 600°C
Electron bombardment heatingThe sample temperature can be more than 1200°C at a maximum current
IR pyrometerIt detects IR radiation from the sample and converts it to temperature in real time using the sample’s emissivity.
Ar ion sputtering gunMaximum energy is 3 keV, and working pressure is ~10⁻⁶ mbar in the preparation chamber.
E-beam evaporation cellRequirements need to be discussed with beamline scientists.
Gases flow into the preparation and main chamberAr, N₂, O₂, etc., gas flowing requirements need to be discussed with beamline scientists.
Load-lock with 2 slots of sample holderTakes at least 1.5 hours (depending on the sample type) to pump down for preparing pressure to transfer a sample into the main chamber without breaking UHV

Support Facilities

Equipment or ComponentDetails
Digital hotplateTemperature range: 5-550°C, ± 2.0°C
Low-to-Mid Range Magnification Digital Microscope LEICA DMS1000The optics ensures magnification of up to 300x. The built-in HDMI microscope camera provides full high definition live images of up to 30 fps and a resolution of 5M pixels.
Ultrasonic cleaner–
Silver epoxy, high temperature Carbon paste–
Cu, Al, Ni platesFor powder sample substrate of powder specimen
Carbon and Copper tape–
Ceramic and Al wire top-postFor cleavable samples
Sample holders–
Desiccator Cabinet–
Spot welding tool–